Versione Stampabile Dillo ad un amico

Salifert Phosphate Po4 Test Kit :: Pareri

Prezzo2,066.20 руб.excl. TAX
Sale1,919.07 руб.excl. TAX
Il Tuo Risparmio147.13 руб. (7%)
Reward Credits9.20 руб.
Qta'
Salifert Phosphate Profi-Test
  • If phosphate is present in too high a concentration there may be an increase in growth of undesirable algae and if the phosphate level is higher than 0.04 mg/L the growth rate of corals and calcareous algae may decrease by as much as 90%.
  • Washing fish food (a rich source of phosphates) after thawing can significantly reduce the input of phosphate, and using a high grade, phosphate free activated carbon can also help to keep phosphate levels as low as possible.
  • The Salifert Phosphate test kit detects, in less than 5 seconds, the level of phosphate present.
  • There are two different ranges within the kit: a low range for phosphate-phosphor from 0.01 - 1 mg/L and a medium range for phosphate-phosphor from 0.02 - 2 mg/L.
  • Sufficient for 60 tests.
  • Can be used for marine, fresh and garden pond water
Specifications 

Erroneous results might be obtained when the carbonate hardness is higher that 20dKH. This corresponds to an alkalinity of 7meq/l. Normally the carbonate hardness is well below the above mentioned values.

Warning!
Irritating: PO4-1 contains < 3.5 M HCL.

R36/37/38: Irritating to eyes, respiratory system and skin.

S26: In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

Instructions:
  1. Add with the syringe 10ml of water in the test vial.
  2. Add to this 4 drops of PO4-1 reagent and swirl the test vial gently for 10 seconds.
  3. Add to this 1 level scoop of PO4-2 reagent and swirl the contents gently for 30 seconds.
  4. Place the open test vial on top of the color shart on a part of the chart which is white and compare the colors looking from the top. Read the corresponding phosphate content. An intermediate color corresponds to an intermediate phosphate content.

    The phosphate values are in ppm Phosphate. If you prefer a reading in ppm Phosphate-Phosphor then divide the reading by 3 or use the table given below.
Higher Sensitivity
Should you require an even higher sensitivity then double the water sample and the reagents. The scale should then be divided by 2.
Filtered By 3 - Medio 1 - Pessimo 4 - Buono Trovato: 0
Valutalo
Name
Email
Sommario su una singola linea
Your Review
Codice di verifica

Name
Email
Your Question
Codice di verifica

Nessuna domanda trovata
Visti di recente
Co2 5K Diffuser
Prezzo698.85 руб.excl. TAX
Sale491.95 руб.excl. TAX
Il Tuo Risparmio206.90 руб. (30%)
segue...
All in one Brine Shrimp Incubator
Prezzo1,967.81 руб.excl. TAX
Sale1,722.29 руб.excl. TAX
Il Tuo Risparmio245.52 руб. (12%)
segue...
Inflow Outflow Lilyp Pipe 17mm L Size
Prezzo4,037.68 руб.excl. TAX
Sale3,345.27 руб.excl. TAX
Il Tuo Risparmio692.41 руб. (17%)
segue...
Fish Catcher for Reef Tank
Prezzo2,459.76 руб.excl. TAX
Sale2,262.98 руб.excl. TAX
Il Tuo Risparmio196.78 руб. (8%)
segue...